China Testing & Certification International Group Co., Ltd. (CTC, Stock Code 603060) originated from the testing and certification business of China Building Materials Academy in the 1950s. After 70 years of unremitting efforts and persistent pursuit, the company has formed five business categories: detection and testing, certification and evaluation, testing instruments and intelligent manufacturing, measurement and calibration, scientific research and technical services, committed to providing customers with technical services and comprehensive solutions of detection and testing, certification and evaluation, appraisal, consultation, training, and instruments and equipment in fields of quality, environmental protection, green, safety, health, and energy conservation.

Building energy efficiency is a comprehensive engineering practice aimed at systematically reducing energy consumption and improving energy utilization efficiency throughout the building’s lifecycle, without compromising functionality or indoor thermal comfort. It integrates innovations in technology, materials, equipment, and management, with the core principles of “reducing demand, improving efficiency, and utilizing green energy.” It has become a key driver for the green and low-carbon transformation of the construction industry. The testing is primarily divided into two categories: energy-efficient materials and on-site energy efficiency.
Building Doors and Windows
Reflective Thermal Insulation Materials
Energy-Efficient Materials
On-Site Energy Efficiency
Air Permeability, Watertightness, Wind Load Resistance, Thermal Insulation Performance, Sound Insulation Performance
Hemispherical Emittance, Solar Reflectance, Near-Infrared Reflectance, Solar Reflectance after Soiling, Change Rate of Solar Reflectance after Soiling
Density, Thermal Conductivity, Moisture Content, Water Absorption, Water Repellency, Short-Term Water Absorption, Long-Term Water Absorption, Vacuum Water Absorption Rate, Compressive Strength, Tensile Strength Perpendicular to Faces, Tensile Bond Strength, Workable Time, Tensile Breaking Force, Alkali-Resistant Breaking Force Retention Rate, Elongation at Break, Volume Water Absorption, Standard Value of Anchor Tensile Load-Bearing Capacity, Reaction to Fire, Oxygen Index, Electrical Resistance, Thermal Transmittance and Thermal Resistance
Field Air Permeability of External Doors/Windows, Field Watertightness of External Doors/Windows, Pull-Out Test for Insulation Anchors, Structure of Insulation Layer, Field Thermal Transmittance or Thermal Resistance of External Walls, Thermal Irregularities, Inner Surface Temperature of Thermal Bridges in the Building Envelope
Aluminum alloy doors/windows, plastic doors/windows, glass fiber reinforced polyurethane energy-saving doors/windows, aluminum-wood composite doors/windows: GB/T 8478, GB/T 28886, JG/T 571, GB/T 29734.1
Reflective thermal insulation materials laboratory testing, reflective thermal insulation material finish layer field testing: JG/T 235, GB/T 25261, GB/T 9780, DG/TJ 08-2038
Expanded polystyrene boards, extruded polystyrene boards, foam glass boards, rock wool boards, inorganic insulation mortar, vacuum insulation panels, composite boards, glass wool boards, interface mortar, anti-cracking mortar, bonding mortar, basecoat mortar, fiberglass mesh, anchors, flexible elastomeric foam insulation products, wires and cables, lamps, fan coil units, heat recovery ventilators: GB/T 10801.1, GB/T 10801.2, JC/T 647, GB/T 17794, GB 8624, GB/T 19686, GB/T 24908, GB/T 19232, GB/T 21087
External doors/windows performance, insulation system, building envelope: GB 50411, DG/TJ 08-2038
Over 20 years of specialized experience in energy efficiency testing.
Comprehensive range of tested energy efficiency product types and parameters.
Participated in the drafting of multiple technical standards, including DG/TJ 08-2038-2021, DG/TJ 08-2433A-2023, DG/TJ 08-2433B-2023.
Links